Home MenuWind-Resistant Contruction Requirements
The Virginia Uniform Statewide Building Code is designed to ensure safety to life and property from all hazards incident to building design and construction at the least possible cost consistent with national recognized standards.
Being located along the Atlantic coastline, Accomack County is subject to many coastal storms, including hurricanes. This is evidenced by the County’s inclusion in the 90 MPH Basic Wind Speed Zone as set forth in the referenced BOCA National Building Code and the CABO One & Two Family Dwelling Code.
For this reason, the following basic construction design standards for all wood residential and commercial structures built in Accomack County will be strictly enforced to help reduce the risk of life and property at a minimal cost to homeowners:
- Approved metal high wind roof rafter-to-top plate tie downs fastened in accordance with the manufacturer’s instructions are required at every connection to reduce uplift.
- Minimum fastening schedules for exterior wall and roof sheathing are 8d common nails fastened no more than four (4") inches on center on edges and no more than six (6") inches on center in the field.
- Asphalt/fiberglass shingle roofing:
- For one and two family dwellings:
- Shingles shall be installed as per shingle manufacturer’s printed instructions for a high wind zone.
- For commerical structures built under the BOCA Code:
- Shingles shall have a minimum of 6 fasteners per shingle section, placed in accordance with the shingle manufacturer's printed instructions.
- For one and two family dwellings:
- Exterior wall sheathing shall either be fastened over the band joist and onto the side of the sill plate, or approved metal connectors shall be fastened as per the connector manufacturer from each wall stud to the sill plate, in required wind exposures.
- Adequate gable end bracing, such as "K-bracing," shall be installed at all gable ends to resist wind loads, and reduce the likelihood of "racking."
The above are enforced to minimize loss of life and property during hurricanes and strong storms and are not intended to serve as the only options for minimum protection.
Winds can far exceed the 90 MPH Basic Wind Speed designated for this area creating major damage to structures which employ even the best building techniques.
It is suggested that licensed design professionals be contacted for further recommendations to increase structural resistance to storms.